Thermistor Averaging 8' Bell Box

Thermistor Averaging 8' Bell Box

Item #: ACIA/3K-A-8-BB
Supplier #: A/3K-A-8'-BB

The copper capillary houses sensing elements which are wired in a series/parallel configuration to provide an averaged output. This unit has a metal bell box (BB) configuration which has a NEMA 3R rating and is designed for wet environments.  3K Ohms @ 77 °F (25 °C) Thermistor

 

Call 513-251-4343 for Availability
UOM : EA
Thermistor Duct 8" Bell Box

Thermistor Duct 8" Bell Box

Item #: ACIA/3K-D-8-BB
Supplier #: "A/3K-D-8""-BB"

3K Ohms @ 77 Deg F (25 Deg C) Thermistor. The metal bell box (BB) configuration has a NEMA 3R rating and is designed for wet environments.

ACI duct temperature sensors are designed for HVAC, Building Automation, and light industrial systems. Specific applications include: zone control, air handling units, and temperature monitoring. 

Call 513-251-4343 for Availability
UOM : EA
Semiconductor Duct 12" Bell Box

Semiconductor Duct 12" Bell Box

Item #: ACIA/592-10K-D-12-BB
Supplier #: "A/592-10K-D-12""-BB"

The A/592-10K provides a three-wire 2.48 to 3.78 VDC output throughout the temperature range of -25 to 105ºC (-13 to 221ºF). The metal bell box (BB) configuration has a NEMA 3R rating and is designed for wet environments.
Call 513-251-4343 for Availability
UOM : EA
Semiconductor Duct 6" Bell Box

Semiconductor Duct 6" Bell Box

Item #: ACIA/592-10K-D-6-BB
Supplier #: "A/592-10K-D-6""-BB"

The A/34 sensor provides a -400 to 2300 mV output throughout the temperature range of -40 to 230ºF. The metal bell box (BB) configuration has a NEMA 3R rating is designed for wet environments. The sensing element is double encapsulated to avoid sensor failures caused by moisture infiltration.

Call 513-251-4343 for Availability
UOM : EA
Semiconductor Outdoor Air Bell Box

Semiconductor Outdoor Air Bell Box

Item #: ACIA/592-10K-O-BB
Supplier #: A/592-10K-O-BB

The A/592-10K provides a three-wire 2.48 to 3.78 VDC output throughout the temperature range of -25 to 105ºC (-13 to 221ºF). The NEMA 3R (Bell Box) is a rated enclosure with an outside sensor probe. It is designed to be mounted flush to an exterior wall.

Call 513-251-4343 for Availability
UOM : EA
Semiconductor Averaging 24' Bell Box

Semiconductor Averaging 24' Bell Box

Item #: ACIA/592-A-24-BB
Supplier #: A/592-A-24'-BB

The 592 provides a 248 to 378 uA output throughout the temperature range of -25 to 105ºC (-13 to 221ºF). This unit has a metal bell box (BB) configuration which has a NEMA 3R rating and is designed for wet environments.
Call 513-251-4343 for Availability
UOM : EA
Semiconductor Averaging 8' Bell Box

Semiconductor Averaging 8' Bell Box

Item #: ACIA/592-A-8-BB
Supplier #: A/592-A-8'-BB

The 592 provides a 248 to 378 uA output throughout the temperature range of -25 to 105ºC (-13 to 221ºF). This unit has a metal bell box (BB) configuration which has a NEMA 3R rating and is designed for wet environments.
Call 513-251-4343 for Availability
UOM : EA
Semiconductor Duct 6" Bell Box

Semiconductor Duct 6" Bell Box

Item #: ACIA/592-D-6-BB
Supplier #: "A/592-D-6""-BB"

The 592 provides a 248 to 378 uA output throughout the temperature range of -25 to 105ºC (-13 to 221ºF). The metal bell box (BB) configuration has a NEMA 3R rating is designed for wet environments. The sensing element is double encapsulated to avoid sensor failures caused by moisture infiltration.

Call 513-251-4343 for Availability
UOM : EA
Thermistor Averaging 24' Bell Box

Thermistor Averaging 24' Bell Box

Item #: ACIA/AN-BC-A-24-BB
Supplier #: A/AN-BC-A-24'-BB

The copper capillary houses sensing elements which are wired in a series/parallel configuration to provide an averaged output. This unit has a metal bell box (BB) configuration which has a NEMA 3R rating and is designed for wet environments.  5.2381K at 77 Deg F (25 Deg C)

Call 513-251-4343 for Availability
UOM : EA
Thermistor Averaging 8' Bell Box

Thermistor Averaging 8' Bell Box

Item #: ACIA/AN-BC-A-8-BB
Supplier #: A/AN-BC-A-8'-BB

The copper capillary houses sensing elements which are wired in a series/parallel configuration to provide an averaged output. This unit has a metal bell box (BB) configuration which has a NEMA 3R rating and is designed for wet environments.  5.2381K at 77 Deg F (25 Deg C)

Call 513-251-4343 for Availability