RTD's Immersion with Well 6" Bell Box

RTD's Immersion with Well 6" Bell Box

Item #: ACIA/100-3W-I-6-BB
Supplier #: "A/100-3W-I-6""-BB"

100 Ohms @ 32 degrees F ( platinum RTD sensing element) with a 0.00385 temperature coefficient in a three wire configuration. The metal bell box (BB) configuration has a NEMA 3R rating and is designed for wet environments. This unit also includes a two-piece 304 stainless steel thermowell which has male 1/2 inch NPT threads. The wells are milled to tight tolerances so there is maximum temperature transfer and this eliminates the need for thermal grease.

Call 513-251-4343 for Availability
UOM : EA
RTD's Immersion No Well 6" Bell Box

RTD's Immersion No Well 6" Bell Box

Item #: ACIA/100-3W-INW-6-BB
Supplier #: "A/100-3W-INW-6""-BB"

100 Ohms @ 32 degrees F ( platinum RTD sensing element) with a 0.00385 temperature coefficient.

The metal bell box, no well configuration has a NEMA 3R rating and is designed for wet environments. It has male 1/2 inch NPT threads and the sensing element is double encapsulated to avoid sensor failures caused by moisture infiltration.  ACI also standardizes with etched Teflon lead wires and wells must be ordered separately for this part.

Call 513-251-4343 for Availability
UOM : EA
RTD's Rigid Averaging 36" Bell Box

RTD's Rigid Averaging 36" Bell Box

Item #: ACIA/100-3W-RA-36-BB
Supplier #: "A/100-3W-RA-36""-BB"

100 Ohms @ 32 degrees F ( platinum RTD sensing element) with a 0.00385 temperature coefficient in a three wire configuration. The metal bell box (BB) configuration has a NEMA 3R rating and is designed for wet environments. The sensing element is double encapsulated to avoid sensor failures caused by moisture infiltration.
Call 513-251-4343 for Availability
UOM : EA
RTD's Flexible Averaging 12' Bell Box

RTD's Flexible Averaging 12' Bell Box

Item #: ACIA/1K-2W-FA-12-BB
Supplier #: A/1K-2W-FA-12'-BB

1000 Ohms @ 32 degrees F ( platinum RTD sensing element) with a 0.00385 temperature coefficient. This metal bell box flexible averaging configuration provides an averaged output based on the cable length ordered.  The enclosure has a NEMA 3R rating and is designed for wet environments.

Call 513-251-4343 for Availability
UOM : EA
RTD's Rigid Averaging 18" Bell Box

RTD's Rigid Averaging 18" Bell Box

Item #: ACIA/1K-2W-RA-18-BB
Supplier #: "A/1K-2W-RA-18""-BB"

1000 Ohms @ 32 degrees F ( platinum RTD sensing element) with a 0.00385 temperature coefficient. The metal bell box (BB) configuration has a NEMA 3R rating and is designed for wet environments.
Call 513-251-4343 for Availability
UOM : EA
RTD's Rigid Averaging 24" Bell Box

RTD's Rigid Averaging 24" Bell Box

Item #: ACIA/1K-2W-RA-24-BB
Supplier #: "A/1K-2W-RA-24""-BB"

1000 Ohms @ 32 degrees F ( platinum RTD sensing element) with a 0.00385 temperature coefficient. This metal bell box rigid averaging configuration has a continuous filament sensing element that provides an averaged output based on the probe length ordered.  The enclosure has a NEMA 3R rating and is designed for wet environments.

Call 513-251-4343 for Availability
UOM : EA
RTD's Rigid Averaging 36" Bell Box

RTD's Rigid Averaging 36" Bell Box

Item #: ACIA/1K-2W-RA-36-BB
Supplier #: "A/1K-2W-RA-36""-BB"

1000 Ohms @ 32 degrees F ( platinum RTD sensing element) with a 0.00385 temperature coefficient. This metal bell box rigid averaging configuration has a continuous filament sensing element that provides an averaged output based on the probe length ordered.  The enclosure has a NEMA 3R rating and is designed for wet environments.

Call 513-251-4343 for Availability
UOM : EA
RTD's Immersion with Well 4" Bell Box

RTD's Immersion with Well 4" Bell Box

Item #: ACIA/1K-3W-I-4-BB
Supplier #: "A/1K-3W-I-4""-BB"

1000 Ohms @ 32 degrees F ( platinum RTD sensing element) with a 0.00385 temperature coefficient in a three wire configuration. The metal bell box (BB) configuration has a NEMA 3R rating and is designed for wet environments. This unit also includes a two-piece 304 stainless steel thermowell which has male 1/2 inch NPT threads. The wells are milled to tight tolerances so there is maximum temperature transfer and this eliminates the need for thermal grease.

Call 513-251-4343 for Availability
UOM : EA
RTD's Immersion with Well 6" Bell Box

RTD's Immersion with Well 6" Bell Box

Item #: ACIA/1K-3W-I-6-BB
Supplier #: "A/1K-3W-I-6""-BB"

1000 Ohms @ 32 degrees F ( platinum RTD sensing element) with a 0.00385 temperature coefficient in a three wire configuration. The metal bell box (BB) configuration has a NEMA 3R rating and is designed for wet environments. This unit also includes a two-piece 304 stainless steel thermowell which has male 1/2 inch NPT threads. The wells are milled to tight tolerances so there is maximum temperature transfer and this eliminates the need for thermal grease.

Call 513-251-4343 for Availability
UOM : EA
RTD's Immersion No Well 4" Bell Box

RTD's Immersion No Well 4" Bell Box

Item #: ACIA/1K-3W-INW-4-BB
Supplier #: "A/1K-3W-INW-4""-BB"

1000 Ohms @ 32 degrees F ( platinum RTD sensing element) with a 0.00385 temperature coefficient. The metal bell box, no well configuration has a NEMA 3R rating and is designed for wet environments. It has male 1/2 inch NPT threads and the sensing element is double encapsulated to avoid sensor failures caused by moisture infiltration.  ACI also standardizes with etched Teflon lead wires and wells must be ordered separately for this part.

Call 513-251-4343 for Availability
UOM : EA