Browse Categories

Search in Category

Tekmar Controls

Browse Categories

Loading...

Tekmar Controls

Controls/Boiler Controls/Tekmar Controls 
Viewing Page 2 of 12 (116 results)
tN2 WIRING CENTER 4 ZONE PUMPS

tN2 WIRING CENTER 4 ZONE PUMPS

Item #: TEK314
Supplier #: 314

The tekmarNet® 2 Wiring Center 314 is designed to provide a zoning solution for heating systems. It can be used in applications ranging from baseboard zones, to radiant heating zones. This product provides power for up to four tekmarNet® 2 thermostats and up to four 115 V (ac) zones pump outputs, as well as providing an end switch closure to enable an external device such as a boiler. An outdoor sensor input is included and provides the outdoor air temperature reading on each thermostat when an optional outdoor sensor is installed.

For Further Information and up to date literature visit: Tekmar Documentation

Avail in Various Locations
UOM : EA
BOILER RESET MODULE 1 tN4 DHW SETPOINT

BOILER RESET MODULE 1 tN4 DHW SETPOINT

Item #: TEK420
Supplier #: 420

The Boiler Reset Module 420 is designed to operate all of the mechanical equipment in a hydronic heating system, except for zones, coordinating their operation through network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler, to multiple radiant floor zones with a modulating/condensing boiler. This control regulates one space heating water temperature through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling a single on/off or modulating boiler, Domestic Hot Water, setpoint loads, and can expand up to 24 zones in total.

For Further Information and up to date literature visit: Tekmar Documentation

Avail in Various Locations
UOM : EA
ADAPTOR PLATE

ADAPTOR PLATE

Item #: TEK012
Supplier #: 012

The Adaptor Plate 012 covers the paint ring left behind when replacing other thermostats, so that no patching or painting the wall is required. The 012 also allows a thermostat to be installed onto a single gang electrical box. The 012 package includes screws for mounting the adaptor plate and the device that attaches to it.

For Further Information and up to date literature visit: Tekmar Documentation

Avail in Various Locations
UOM : EA
tN2 WIRING CENTER 4 ZONE VALVE

tN2 WIRING CENTER 4 ZONE VALVE

Item #: TEK313
Supplier #: 313

The tekmarNet® 2 Wiring Center 313 is designed to provide a zoning solution for heating systems. It can be used in applications ranging from baseboard zones, to remote manifolds for radiant heating. This product provides power for up to four tekmarNet® 2 thermostats, and up to four 24 V (ac) zones valve outputs, as well as providing an end switch closure to enable an external device such as a boiler. A line voltage output on the back of the control can operate a zone group pump if required. An outdoor sensor input is included and provides the outdoor air temperature reading on each thermostat when an optional outdoor sensor is installed.

For Further Information and up to date literature visit: Tekmar Documentation

Avail in Various Locations
UOM : EA
tekmarNet TSTAT 1 STG HT/COOL 1 FAN

tekmarNet TSTAT 1 STG HT/COOL 1 FAN

Item #: TEK554
Supplier #: 554

The tekmarNet® Thermostat 554 is a communicating touchscreen thermostat designed to operate one heating stage, one cooling stage, and a fan. The heating stage can be either hydronic or forced air and the cooling stage can operate an air conditioner. There are two auxiliary sensor inputs available to measure room, floor, outdoor, coil or duct temperature. The optional floor sensor allows precise heating of radiant floors by controlling the floor temperature and maintaining the desired room air temperature. The large touchscreen allows you to easily adjust 7-day programmable schedules and room temperature to optimize comfort and energy savings. The 554 can connect to tekmarNet controls using two or four wires or it can operate as a stand-alone thermostat using three wires.

For Further Information and up to date literature visit: Tekmar Documentation

Avail in Various Locations
UOM : EA
tekmarNet THERMOSTAT RADIANT FLOOR

tekmarNet THERMOSTAT RADIANT FLOOR

Item #: TEK557
Supplier #: 557

The tekmarNet® Thermostat 557 is a communicating touchscreen thermostat designed to operate either: a hydronic radiant floor with a two stage heat pump (water-to-air or air-to-air) for heating & cooling and an emergency backup heating system; or two stages of heating and two stages of cooling. There are three auxiliary sensor inputs that can be used to measure room, floor, outdoor or duct temperature. The optional floor sensor allows precise heating of radiant floors. Relative humidity level can be measured and controlled using either the built-in or external humidity sensor. The large touchscreen display allows you to easily adjust 7-day programmable schedules and room temperatures to optimize comfort and energy savings. The 557 can connect to tekmarNet® controls using two or four wires or it can operate as a stand-alone device.

For Further Information and up to date literature visit: Tekmar Documentation

Avail in Various Locations
UOM : EA
SNOW MELTING CONTROL

SNOW MELTING CONTROL

Item #: TEK654
Supplier #: 654

The Snow Melting Control 654 is designed to operate electric or hydronic equipment to melt snow or ice from any surface including driveways, walkways, patios, business entrances, parking ramps, loading docks, hospital entrances, helipads or car wash bays. The surface temperature for snow melting is controlled automatically to reduce operating energy costs. The 654 has an automatic start and stop function when used with the Snow/Ice Sensor 090 or 094. Automatic start with a timed stop is available when used with the Snow Sensor 095. The 654 can operate a dedicated hydronic boiler or a mixing device. Isolation relays are required to operate line voltage pumps. Electric systems require a separate GFCI and electrical relay contactor.

For Further Information and up to date literature visit: Tekmar Documentation

Avail in Various Locations
UOM : EA
UNIVERSAL SENSOR 8' (2.4 M) WIRE

UNIVERSAL SENSOR 8' (2.4 M) WIRE

Item #: TEK082
Supplier #: 082

The Universal Sensor 082 is a 10 k? temperature sensor designed to be strapped onto a pipe. It can be used with any tekmar control sensor input, but is most commonly used to monitor supply and return water temperatures. This product has a brass sleeve for fast response, a wide operating range, an indent to allow pipe strap on installation, and 8 ft (2.4 m) of 2-conductor wire.

For Further Information and up to date literature visit: Tekmar Documentation

Avail in Various Locations
UOM : EA
ONE STAGE SETPOINT CONTROL

ONE STAGE SETPOINT CONTROL

Item #: TEK150
Supplier #: 150

The One Stage Setpoint Control 150 is designed to operate a single component of a heating or cooling system in order to maintain a set temperature. It can be used in applications ranging from heating a swimming pool to maintaining a constant slab temperature in a commercial car wash bay. This control regulates a constant setpoint water temperature for heating or cooling. The 150 is designed to operate a single relay (rated at 240 V, 8 A) to control a single device such as a boiler, pump, or valve.

For Further Information and up to date literature visit: Tekmar Documentation

Avail in Various Locations
UOM : EA
OBSOLETE SEE TEK284

OBSOLETE SEE TEK284

Item #: TEK263
Supplier #: 263

The Boiler Control 263 is designed to stage multiple boilers or operate a modulating boiler using Outdoor Temperature Reset. It can be used in applications ranging from a single zone of baseboard, multiple baseboard and fan coil zones, to dedicated Domestic Hot Water heating in commercial buildings. This control regulates a single heating water temperature through Outdoor Temperature Reset, setpoint, and DHW target control. It is capable of controlling (stage and rotate) up to 2 on/off boilers, a single 2 stage boiler, or 1 modulating boiler as well as the system pump.

For Further Information and up to date literature visit: Tekmar Documentation

Avail in Various Locations
UOM : EA