Search in Category
Filter Your Search
Browse Categories
Tekmar Controls
BOILER CONTROL 4 Tn4 BAS
Supplier #: 284
The Boiler Control 284 is designed to operate up to four boilers to accurately maintain a target water temperature. The 284 operates both condensing & non-condensing boilers that are either modulating, single stage or two stage to provide a flexible, cost effective mixed boiler plant solution with better system performance. The target water temperature is based on outdoor temperature reset or a fixed setpoint for space or process heating applications. Additional loads supplied by the 284 include domestic hot water & fixed setpoint heating. Boiler equal run-time rotation, stand-by primary pump operation & pump exercising all increase boiler plant reliability. The 284 communicates with a Building Automation System (BAS) using BACnet® or Modbus® for remote monitoring & adjustment capability. tekmarNet® Thermostats or a tN4 Gateway 485 can be added to optimize system performance & provide remote monitoring capability.
For Further Information and up to date literature visit: Tekmar Documentation
tN4 ZONE EXPANSION MODULE
Supplier #: 326
The tekmarNet® 4 Zone Expansion Module 326 is designed to provide expansion for a zoning solution for heating systems. It can be used in applications ranging from baseboard zones, to radiant heating manifolds. This product expands the number of zones provided with a Zone Manager by up to 3 more zone pumps. It is capable of providing power for up to 3 tekmarNet® 4 or stand alone thermostats and energizing their respective 115 V (ac) zones, as well as providing a powered Zone Group Pump (powered end switch) contact to enable an external device such as a manifold pump.
For Further Information and up to date literature visit: Tekmar Documentation
tN2 ZONE MANAGER
Supplier #: 334
The tekmarNet® 2 Zone Manager 334 is designed to provide a zoning solution for 2-wire tekmarNet® 2 thermostats used in heating systems. It can be used in applications ranging from baseboard zones, to remote manifolds for radiant heating. This control energizes up to 4 zone valves or zone pumps. It is capable of providing power for up to 4 tekmarNet® 2 thermostats and energizing their respective 24 V (ac) or 115 V (ac) zones, as well as providing a powered Zone Group Pump (powered end switch) contact to enable an external device such as a manifold pump.
For Further Information and up to date literature visit: Tekmar Documentation
tN4 ZONE MANAGER
Supplier #: 335
The tekmarNet® 4 Zone Manager 335 is designed to provide a zoning solution for heating systems. It can be used in applications ranging from baseboard zones, to radiant heating manifolds. This product can operate up to 6 zone valves. It is capable of providing power for up to 6 tekmarNet® 4 or stand alone thermostats and energizing their respective 24 V (ac) zones, as well as providing a powered Zone Group Pump (powered end switch) contact to enable an external device such as a manifold pump.
For Further Information and up to date literature visit: Tekmar Documentation
tN4 ZONE MANAGER
Supplier #: 336
The tekmarNet® 4 Zone Manager 336 is designed to provide a zoning solution for heating systems. It can be used in applications ranging from baseboard zones, to radiant heating zones. This product energizes up to 4 zone pumps. It is capable of providing power for up to 4 tekmarNet® 4 or stand alone thermostats and energizing their respective 115 V (ac) zones, as well as providing a Zone Group Pump (powered end switch) contact to enable an external device such as a primary secondary loop pump.
For Further Information and up to date literature visit: Tekmar Documentation
POWER MANAGER 3 AUXILIARY PUMP 4 DEMAN
Supplier #: 346
The Power Manager 346 is designed to allow non-tekmar products to interface with a tekmarNet® 4 communicating heating system. It can be used in applications that use 3rd party thermostats, zoning devices, or mechanical equipment that requires a hot water demand from the boiler system. This product provides demand inputs for up to 4 different reset water temperatures (high temp, low temp 1, low temp 2, low temp 3). It has the capability of switching 3 pump outputs and provides wiring for up to 3 tekmarNet® 4 devices, as well as the 4 separate demand inputs to create a heat call on one of up to 4 possible reset water temperatures.
For Further Information and up to date literature visit: Tekmar Documentation
MIXING CONTROL VARIABLE SPEED
Supplier #: 356
The Mixing Control 356 is designed to operate a mixing pump to control the temperature in a hot water heating system using Outdoor Temperature Reset. It can be used in applications ranging from in-floor radiant to commercial baseboard systems for boiler protection with full reset. This control regulates a single heating water temperature through Outdoor Temperature Reset. It provides mixing by speeding up or slowing down a single permanent capacitor (standard wet rotor) circulator.
For Further Information and up to date literature visit: Tekmar Documentation
MIXING CONTROL FLOATING ACTION
Supplier #: 360
The Mixing Control 360 is designed to operate a mixing valve using Outdoor Temperature Reset. It can be used in applications ranging from in-floor radiant to commercial baseboard systems for Boiler Return Protection with full reset. This control regulates a single heating water temperature through Mixing Outdoor Reset. It controls the mixing by opening or closing a floating action type mixing valve actuator (3 or 4 way valves), and also provides control of the mix system pump.
For Further Information and up to date literature visit: Tekmar Documentation
tN2 HOUSE CNTRL BOILER MXNG 4 ZONE VLV
Supplier #: 402
The tekmarNet® 2 House Control 402 is designed to operate all the mechanical equipment in a residential hydronic heating system, coordinating their operation through network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler to multiple fan coils, mixed radiant floor heating zones, and a modulating/condensing boiler. This control regulates up to two heating water temperatures through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling a single on/off, two stage, or modulating boiler, a mixing device, Domestic Hot Water, setpoint loads, 4 on-board zone valves, and can expand up to 24 zones in total for each space heating water temperature.
For Further Information and up to date literature visit: Tekmar Documentation
tN2 HOUSE CNTRL BOILER MXNG 4 ZONE PUM
Supplier #: 403
The tekmarNet® 2 House Control 403 is designed to operate all of the mechanical equipment in a residential hydronic heating system, coordinating their operation through network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler, to multiple fan coils, mixed radiant floor heating zones, and a modulating/condensing boiler. This control regulates up to two heating water temperatures through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling a single on/off, two stage, or modulating boiler, a mixing device, Domestic Hot Water, setpoint loads, 4 on-board zone pumps, and can expand up to 24 zones in total for each space heating water temperature.
For Further Information and up to date literature visit: Tekmar Documentation