BOILER CNTRL 1 tN4 MODULATING BLR DHW

BOILER CNTRL 1 tN4 MODULATING BLR DHW

Item #: TEK275
Supplier #: 275

The Boiler Control 275 is designed to stage up to four condensing or non-condensing, modulating or on-off boilers using P.I.D. staging to accurately maintain temperature. Water temperature is controlled by Outdoor Temperature Reset for space heating applications or a fixed setpoint for Domestic Hot Water (DHW) tank heating or industrial process heating applications. The control will also accept an analog 0-10 V (dc) signal from an Energy Management System (EMS) to control the water temperature. Boiler Equal Run Time Rotation, pump exercising and stand-by system pump operation increase boiler plant reliability. The control is tekmarNet® communication compatible allowing for internet connectivity using an optional Gateway 483.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
BOILER CONTROL 4 Tn4 BAS

BOILER CONTROL 4 Tn4 BAS

Item #: TEK284
Supplier #: 284

The Boiler Control 284 is designed to operate up to four boilers to accurately maintain a target water temperature. The 284 operates both condensing & non-condensing boilers that are either modulating, single stage or two stage to provide a flexible, cost effective mixed boiler plant solution with better system performance. The target water temperature is based on outdoor temperature reset or a fixed setpoint for space or process heating applications. Additional loads supplied by the 284 include domestic hot water & fixed setpoint heating. Boiler equal run-time rotation, stand-by primary pump operation & pump exercising all increase boiler plant reliability. The 284 communicates with a Building Automation System (BAS) using BACnet® or Modbus® for remote monitoring & adjustment capability. tekmarNet® Thermostats or a tN4 Gateway 485 can be added to optimize system performance & provide remote monitoring capability.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
MIXING CONTROL FLOATING ACTION

MIXING CONTROL FLOATING ACTION

Item #: TEK360
Supplier #: 360

The Mixing Control 360 is designed to operate a mixing valve using Outdoor Temperature Reset. It can be used in applications ranging from in-floor radiant to commercial baseboard systems for Boiler Return Protection with full reset. This control regulates a single heating water temperature through Mixing Outdoor Reset. It controls the mixing by opening or closing a floating action type mixing valve actuator (3 or 4 way valves), and also provides control of the mix system pump.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
tN2 HOUSE CONTROL BOILER 4 ZONE VALVES

tN2 HOUSE CONTROL BOILER 4 ZONE VALVES

Item #: TEK400
Supplier #: 400

The tekmarNet® 2 House Control 400 is designed to operate all of the mechanical equipment in a residential hydronic heating system, coordinating their operation with network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler, to multiple radiant floor zones with a modulating/condensing boiler. This control regulates one space heating water temperature through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling a single on/off, two stage, or modulating boiler, Domestic Hot Water, setpoint loads, 4 on-board zone valves, and can expand up to 24 zones in total.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
tN2 HOUSE CONTROL HEAT PUMP

tN2 HOUSE CONTROL HEAT PUMP

Item #: TEK406
Supplier #: 406

The tekmarNet®2 House Control 406 is designed to operate the equipment in a 2-pipe, single tank, hydronic heating and cooling system. It operates two heat pump stages (water-to-water or air-to-water) with a backup heat source (boiler or electric resistance). The heat pump provides either hot or chilled water to a storage tank loop and optional mixed temperature loop. For radiant heating, the water temperature is calculated using Outdoor Temperature Reset. For radiant cooling, the chilled water temperature is maintained at an adjustable setpoint, or is adjusted using dew-point reset with a humidity sensor. A backup boiler can provide an Outdoor Temperature Reset water temperature as well as domestic hot water and setpoint water temperatures. The 406 operates 4 on-board heating and cooling zones and is expandable up to 52 zones on the boiler, tank, and mix water temperatures.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
PROGRAMMABLE TSTAT 2 HT/ HT-COOL

PROGRAMMABLE TSTAT 2 HT/ HT-COOL

Item #: TEK521
Supplier #: 521

The Programmable Thermostat 521 is designed for three different modes of operation: single stage heating, two stages of heating with a fan, or one stage of heating and one stage of cooling with a fan. Two auxiliary sensors may be added to measure the floor, outdoor or room temperature. A Slab Sensor 079 is included to measure floor temperature to protect the floor from overheating and enhance comfort. The programmable schedule supports either a 7 day or 24 hour schedule with 2 or 4 events per day. A permanent temperature hold button overrides the programmable schedule. An optional Adaptor Plate 012 is available to allow the thermostat to mount onto a single gang electrical box.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
tekmarNet THERMOSTAT 1 STAGE HEAT

tekmarNet THERMOSTAT 1 STAGE HEAT

Item #: TEK552
Supplier #: 552

The tekmarNet® thermostat 552 is a communicating touchscreen thermostat designed for hydronic heating systems. The extra large touchscreen display allows you to easily adjust 7-day programmable schedules and room temperatures to optimize comfort and energy savings. It operates a single zone of heating and has two auxiliary sensor inputs that can be assigned to measure room, floor, or outdoor temperature. An optional floor sensor allows precise heating of radiant floors by controlling the floor temperature and maintaining the desired room air temperature. Alternatively the room air temperature sensor can also be disabled to solely maintain a minimum floor temperature. The 552 can be wired using 2 or 4 wires to connect to tekmarNet® zoning controls, or can be installed as a stand-alone thermostat using 3 wires.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
3-WAY MIXING VALVE 3/4 BRASS

3-WAY MIXING VALVE 3/4 BRASS

Item #: TEK710
Supplier #: 710

The 3-Way Brass Mixing Valve 710 is used to mix supply water from a hydronic source with water returning from a system. It is designed for use in either closed loop or open loop hydronic systems. This 3-way valve has standard female NPT threads, as well as a maximum leak through rate of 1% to allow for water expansion during temperature changes. The valve position can be manually set using the handle. An Actuating Motor 741 can be used to automatically operate the valve.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
3-WAY MIXING VALVE 1 BRASS

3-WAY MIXING VALVE 1 BRASS

Item #: TEK711
Supplier #: 711

The 3-Way Brass Mixing Valve 711 is used to mix supply water from a hydronic source with water returning from a system. It is designed for use in either closed loop or open loop hydronic systems. This 3-way valve has standard female NPT threads, as well as a maximum leak through rate of 1% to allow for water expansion during temperature changes. The valve position can be manually set using the handle. An Actuating Motor 741 can be used to automatically operate the valve.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
3-WAY MIXING VALVE 1-1/4 BRASS

3-WAY MIXING VALVE 1-1/4 BRASS

Item #: TEK712
Supplier #: 712

The 3-Way Brass Mixing Valve 712 is used to mix supply water from a hydronic source with water returning from a system. It is designed for use in either closed loop or open loop hydronic systems. This 3-way valve has standard female NPT threads, as well as a maximum leak through rate of 1% to allow for water expansion during temperature changes. The valve position can be manually set using the handle. An Actuating Motor 741 can be used to automatically operate the valve.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA